瑞申型号 | 感值±20% (µH) | 直流阻抗(mΩ) | 自协频率MHZ | 温升电流(A) | 饱和电流(A) | 对应线艺规格 | ||
标准 | 最大 | 上升20° | 上升40° | |||||
RSAL1580-R40M | 0.4uh | 0.5 | 0.7 | 53.0 | 47.0 | 60.0 | 111.0 | XAL1580-401ME |
RSAL1580-R74M | 0.74uh | 0.72 | 0.86 | 35.1 | 43.2 | 59.7 | 86.0 | XAL1580-741ME |
RSAL1580-1R0M | 1uh | 0.93 | 1.12 | 30.0 | 40.6 | 57.5 | 73.5 | XAL1580-102ME |
RSAL1580-1R3M | 1.3uh | 1.15 | 1.38 | 26.2 | 34.6 | 46.7 | 65.0 | XAL1580-132ME |
RSAL1580-1R8M | 1.8uh | 1.61 | 1.93 | 21.3 | 33.2 | 43.8 | 57.0 | XAL1580-182ME |
RSAL1580-2R0M | 2uh | 1.91 | 2.29 | 20.1 | 29.5 | 39.9 | 51.0 | XAL1580-202ME |
RSAL1580-3R0M | 3uh | 2.62 | 3.10 | 16.0 | 25.6 | 34.4 | 43.0 | XAL1580-302ME |
RSAL1580-4R5M | 4.5uh | 3.82 | 4.58 | 12.5 | 20.4 | 27.0 | 34.2 | XAL1580-452ME |
RSAL1580-5R3M | 5.3uh | 4.35 | 5.22 | 11.8 | 19.5 | 26.5 | 33.0 | XAL1580-532ME |
RSAL1580-6R1M | 6.1uh | 5.66 | 6.79 | 11.7 | 16.9 | 22.6 | 31.0 | XAL1580-612ME |
混合气体等离子体 虽然目前所用的ICP主要采用氩气,引入其他种类气体对实际测试可达到非常有用的效果。Fassel型炬管不适合用于引入其他种类气体,即便在较低浓度范围内,也会使等离子体熄灭。等离子火焰是否容易熄灭取决于仪器RF调谐电路的设计。逐步增加引入气体流量可避免等离子火焰熄灭。一些仪器采用另一种气体引入方式,同时利用另一个质量流量计,确保引入的气体流量准确。此外,也可使用气体混匀器。
ICP-MS中可以使用氮气以减少干扰。可以在冷却气中加入[2]或雾化气中加入[3]氮气,减少各种干扰,如40Ar35Cl+对75As+及氧化物干扰。若在冷却气中加入氮气,则需提高氮气所占体积分数(5%~10%),才能获得良好效果,即在冷却气中加入氮气效果不如在雾化气中加入氮气。在雾化气中加入氮气,研究表明体积分数为4.5%时,即可有效消除1%氯离子干扰。
此时干扰消除机制仍无法确定,但可以通过观察质谱谱图来讨论相应机制。40Ar35Cl+造成质荷比m/z 75处(40Ar37Cl+对应质荷比m/z 77)的信号降低时,质荷比m/z 49及51处(分别由35Cl14N+及37Cl14N+造成)信号相应增大。似乎存在某种优先竞争反应,即与Ar相比,N优先与Cl反应。氮气的引入对等离子体物理及电性质具有重要影响。若在雾化气中加入,则等离子环面明显增大。
此外,雾化气中加入氮气后,使电子温度降低3000~5000K,RSAL1580-2R0M同时气体动力学温度小幅降低,但仍足够明显。因此,虽然在雾化气中加入氮气能明显降低干扰,但同时也造成灵敏度下降[4]。但是,此时并未严重影响大部分样品分析。一些研究人员在冷却气中加入氮气,报道称信号抑制有限,且某些元素的灵敏度实际上提高了一些[5]。Uchida及Ito报道了以氮气为主(即冷却气中只加入少量氩气)的等离子体中相关情况[6],报道称此种等离子体降低了氩相关离子干扰,因此能进行As及Se的测定,但增加了氮相关离子干扰。此外,第一电离能小于6.5eV的元素灵敏度增加,而第一电离能大于6.5eV的元素灵敏度下降。